Potentiometric Titration
Many Acid-Base titrations are difficult to accomplish using a visual indicator for one of several reasons. Perhaps the analyst is color-blind to a particular indicator color change; there may not be a suitable color change available for a particular type of titration or the solutions themselves may be colored, opaque or turbid. It may be desired to automate a series of replicate determinations. In such situations, potentiometric titration, using a glass hydronium ion selective electrode, a suitable reference electrode and a sensitive potentiometer (a pH meter) may be advantageous.
Theory
Any acid-base titration may be conducted potentiometrically. Two electrodes, after calibration [to relate potential in millivolts (mV) to a pH value] are immersed in a solution of the analyte. One is an indicator electrode, selective for H3O+ and the other a stable reference electrode. The potential difference, which after calibration is pH, is measured after the successive addition of known increments of acid or base titrant.
When a potentiometric titration is being performed, interest is focused upon changes in the emf of an electrolytic cell as a titrant of known concentration is added to a solution of unknown. The method can be applied to all titrimetric reactions provided that the concentration of at least one of the substances involved can be followed by means of a suitable indicator electrode. The critical problem in a titration is to recognize the point at which the quantities of reacting species are present in equivalent amounts. The titration curve can be followed point by point, plotting as ordinant, successive values of the cell emf (pH) vs the corresponding volume of titrant added.
The Reference Electrode
Most commonly, the reference electrode is the silver/silver chloride electrode. The potential is based on the following equilibrium:
AgCl(s) + e Ag(s) + Cl-(aq)
The half cell is:
Ag[(AgCl(Sat'd),KCl(xM)]
NOTE: Electrodes respond to the activity of the electroactive species in solution. However, as a practical matter it is more convenient experimentally to use concentration. For this reason the discussion in this laboratory experiment will be made in terms of concentration rather than the more correct activities.
| Name* : |
|||||
| Email* : |
|||||
| Country* : |
|||||
| Phone* : |
|||||
| Subject* : |
|||||
| Upload Homework : Upload another homework (upto 5 uploads max.)
|
|||||
| Due Date |
Time |
AM/PM |
Timezone |
||
| Instructions |
|||||
|
|||||
| Courses/Topics we help on | ||
| Qualitative Analysis | Confidence Interval for Mean & Proportions | Nomenclature of Inorganic Compounds |
| Stoichiometry | Bonding |
Inter Molecular Force |
| Lewis Structure-VSEPR Theory-Shapes of Molecular Models | Chemical Kinetics | Concentration of Solution: Molarity, Molality and Normality |
| Clausius-Clapeyron Equation | Nomenclature of Organic Compounds | Fundamentals of Organic Chemistry |
| Balancing the Chemical Equation by Ion-Electron Method or Redox Method | Classification of Chemical Reactions | Chemistry of Transition Elements |
| Coordination Chemistry | Molecular and Empirical Formula of Organic and Inorganic Compounds | Gas Laws, Charles Law, Boyle's Law, Ideal and Real Gas Equation |
| Periodic Properties of Elements | Substitution and Elimination Reaction | ThermoChemistry |
| Chemical Equilibrium | Rate Law, Order and Molecularity | Nuclear Chemistry |
| Fundamentals of Inorganic Chemistry | Chemistry of Representative Elements | Isomerism in Organic and Inorganic Compounds |
| Electronic Configuration of Elements | Parametric Equations | IB Chemistry |
| Thermodynamics | Periodic properties | Aromaticity |
| IUPAC nomenclature | Chemical bonding | Isomerism |
| Chemical kinetics | Chemical equilibrium | Reward Management |
| Co-ordination chemistry | Nuclear chemistry | Stereochemistry |
| Photochemistry | Chromatography | Spectroscopic techniques |
| Group theory | Organic reaction mechanism | Organometallic complexes |
| Reagents in organic synthesis | Natural products | Quantum chemistry |